• ½ÅÁ¦Ç°
  • Á¦Ç°¼Ò°³
    • ·¹ÄÚ´õ
    • Àü·Â°è
    • ȸ·Î¼ÒÀÚ ÃøÁ¤±â
    • ½ÅÈ£¹ß»ý±â
    • ȯ°æÃøÁ¤±â
    • Ŭ·¥ÇÁ¼¾¼­
    • ÇöÀå¿ë Å×½ºÅͱâ
    • ¾ÈÀü±Ô°Ý ÃøÁ¤±â
    • °Å¸®ÃøÁ¤±â
    • ÁÖº¯Àåºñ/¿É¼Ç
    • PCB °Ë»çÀåºñ-ATEÀåºñ
  • ±â¼úÀÚ·á
    • Ä«´Þ·Î±×
    • ¸Þ´º¾ó
    • ¼ÒÇÁÆ®¿þ¾î
  • Àû¿ë»ç·Ê
    • ·¹ÄÚ´õ
    • Àü·Â°è
    • LCR ¹ÌÅÍ
    • ÀúÀúÇ×°è
    • ±âŸ
  • °í°´¼¾ÅÍ
    • °øÁö»çÇ×
    • °ßÀû¿äû
    • A/S ¼¾ÅÍ
    • Á¦Ç° ¹®ÀÇ
    • 1:1 Ä£Àý »ó´ã
    • ¸Þ´º¾ó »ó´ã
    • Á¤Ç°È®ÀÎ
    • FAQ
    • Contact Us
  • ä¿ëÁ¤º¸
    • ä¿ë°ø°í
  • ȸ»ç¼Ò°³
    • Àλ縻
    • ȸ»çÁ¶Á÷µµ
    • ȸ»ç À§Ä¡ ¹× ¿µ¾÷¼Ò
    • ISO 9001 Á¤º¸
  • ·¹ÄÚ´õ
  • Àü·Â°è
  • ȸ·Î¼ÒÀÚ ÃøÁ¤±â
  • ½ÅÈ£¹ß»ý±â
  • ȯ°æÃøÁ¤±â
  • Ŭ·¥ÇÁ¼¾¼­
  • ÇöÀå¿ë Å×½ºÅͱâ
  • ¾ÈÀü±Ô°Ý ÃøÁ¤±â
  • °Å¸®ÃøÁ¤±â
  • ³»Àü¾ÐÃøÁ¤±â
  • ÁÖº¯Àåºñ/¿É¼Ç
  • PCB °Ë»çÀåºñ-ATEÀåºñ





52³â È÷¿ÀÅ° Çѱ¹À¯Åë ŽŻó»ç
HOME > Á¦Ç°¼Ò°³ > Á¦Ç°Á¤º¸


8958
SCANNER UNIT
Á¦Ç°¹øÈ£ : 8958
Á¦ Ç° ¸í  : 16ch SCANNER UNIT
Á¦Ç°ºÐ·ù : ¿É¼Ç/ÁÖº¯ÀåÄ¡
 
  
 
¡¤ Recorder 16ch SCANNER UNIT 8958
Measurement functions Number of channels: 16, for voltage measurement/temperature measurement with thermocouple
Input connectors Voltage input/Thermocouple input: screw-type terminal strip, recommended wire diameter *1, detachable terminal block (with cover) *1 Recommended cable, singlewire: 0.14 to 1.5 mm2, braided wire 0.14 to 1.0 mm2 (conductor wire diameter min. 0.18 mm), AWG 26 to 16
Input impedance: 1 M§Ù, 850 k§Ù with line fault detection ON, Max. rated voltage to earth: 33 Vrms or 70 V DC (with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage)
Voltage measurement range 5m, 50m, 500m, 2 V/division, 4 ranges, full scale: 20 divisions, measurement range: ¡¾100% of full scale, digital filter: 50/60/10 Hz, measurement resolution 1/1600 of measurement range (using 16-bit A/D conversion; installed in 8860/8861)
Temperature measurement range
(Upper and lower limit values depend on measurement input range of sensor)
10¡ÆC/division (-100¡ÆC/ to +200¡ÆC), 50¡ÆC/division (-200¡ÆC/ to +1000¡ÆC),
100¡ÆC/division (-200¡ÆC/ to +2000¡ÆC), 3 ranges, full scale: 20 divisions,
digital filter: 50/60/10 Hz, measurement resolution 1/1000 of measurement range (using 16-bit A/D conversion; installed in 8860/8861)
Thermocouple range
(JIS C 1602-1995)
(ASTM E-988-96)
K: -200 to 1350¡ÆC, J: -200 to 1200¡ÆC, E: -200 to 1000¡ÆC, T: -200 to 400¡ÆC, N: -200 to 1300¡ÆC, R: 0 to 1700¡ÆC, S: 0 to 1700¡ÆC, B: 400 to 1800¡ÆC, W (WRe5-26): 0 to 2000¡ÆC, reference junction compensation: internal/ external (switchable), line fault detection ON/OFF switchable
Data refresh rate 50 ms/all channels (digital filter OFF), 300 ms/all channels (digital filter 50/60 Hz), 1.4 s/all channels (digital filter 10 Hz)
Accuracy Voltage: ¡¾0.2% of full scale, thermocouple (K, J, E, T, N): ¡¾0.05% of full scale ¡¾1¡ÆC, (R, S, B, W): ¡¾0.05% of full scale ¡¾2¡ÆC (400¡ÆC or more), ¡¾0.05% of full scale ¡¾3.5¡ÆC (less than 400¡ÆC), reference junction compensation accuracy: ¡¾1¡ÆC (added to measurement accuracy with internal reference junction compensation)
Max. allowable input 40 V DC (the maximum voltage that can be applied across input pins without damage)
Dimensions and mass approx. 170 (6.69in) W ¡¿ 20 (0.79in) H ¡¿ 183 (7.20in) D mm, approx. 385 g (13.6 oz)
Accessories Flathead screwdriver ¡¿ 1, short bar ¡¿ 2




9197 CONNECTION CORD
9198 CONNECTION CORD
9665 PROBE
9666 100:1 PROBE
For up to 500 V, 1.5 m (4.92 ft) length For up to 300 V, 1.5 m (4.92 ft) length Grounding voltage is the same as for the unit, 1.5 m (4.92 ft) length Grounding voltage is the same as for the unit, 1.5 m (4.92 ft) length
     
     
9217 CONNECTION CORD
     
Insulation BNC-to-insulation BNC, use to connect to insulation-BNC terminal on Input Module  

 

 